Human TPO (Thrombopoietin) ELISA Kit 96 Test

د.إ 2,568.33
31 people are viewing this right now
Available on backorder
Free Shipping & Returns:
On all orders over د.إ 400.00
MBS2511051
Brand:

Description

Human TPO (Thrombopoietin) ELISA Kit 96 Test

Product Name

TPO, ELISA Kit

Full Product Name

Human TPO (Thrombopoietin) ELISA Kit

OMIM
274500
3D Structure
ModBase 3D Structure for P07202
Species Reactivity
Specificity
This assay has high sensitivity and excellent specificity for detection of Human TPO. No significant cross-reactivity or interference between Human TPO and analogues was observed. Note: Limited by current skills and knowledge, it is impossible for us to complete the cross- reactivity detection between Human TPO and all the analogues, therefore, cross reaction may still exist.
Samples
Serum, Plasma, Biological Fluids
Assay Type
Sandwich
Detection Range
31.25-2000pg/mL
Sensitivity
Min: 18.75pg/mL; Max: 2000pg/mL
Preparation and Storage
Store at 4 degree C.
ISO Certification
Manufactured in an ISO 9001:2015 Certified Laboratory.
Product Note
Select online data sheet information is drawn from bioinformatics databases, occasionally resulting in ambiguous or non-relevant product information. It is the responsibility of the customer to review, verify, and evaluate the information to make sure it matches their requirements before purchasing the kit. Our ELISA Kit assays are dynamic research tools and sometimes they may be updated and improved. If the format of this assay is important to you then please request the current manual or contact our technical support team with a presales inquiry before placing an order. We will confirm the current details of the assay. We cannot guarantee the sample manual posted online is the most current manual, it is intended to serve as an example only. Please refer to the instructions For Use provided with the assay kit for precise details.
Other Notes
Small volumes of TPO elisa kit vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply.
Searchable Terms for TPO purchase
MBS2511051 is a ready-to-use microwell, strip-or-full plate ELISA (enzyme-linked immunosorbent assay) Kit for analyzing the presence of the TPO, ELISA Kit target analytes in biological samples. The concentration gradients of the kit standards or positive controls render a theoretical kit detection range in biological research samples containing TPO. The ELISA analytical biochemical technique of the MBS2511051 kit is based on TPO antibody-TPO antigen interactions (immunosorbency) and an HRP colorimetric detection system to detect TPO antigen targets in samples. The ELISA Kit is designed to detect native, not recombinant, TPO. Appropriate sample types may include undiluted body fluids and/or tissue homogenates, secretions. Quality control assays assessing reproducibility identified the intra-assay CV (%) and inter-assay CV(%).

 

Related Product Information for
TPO elisa kit
Description: The kit is a sandwich enzyme immunoassay for in vitro quantitative measurement of TPO in human serum, plasma and other biological fluids
Principle of the Assay: This ELISA kit uses Sandwich-ELISA as the method. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to Human TPO. Standards or samples are added to the appropriate micro ELISA plate wells and bound by the specific antibody. Then a biotinylated detection antibody specific for Human TPO and Avidin-Horseradish Peroxidase (HRP) conjugate is added to each micro plate well successively and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human TPO, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm +/- 2 nm. The OD value is proportional to the concentration of Human TPO. You can calculate the concentration of Human TPO in the samples by comparing the OD of the samples to the standard curve.

 

Mybiosource

Founded originally in Vancouver, British Columbia in 2006 by three enthusiastic entrepreneurs passionate about providing the best biological reagents worldwide, MyBiosource, Inc. was incorporated as a company with big visions. Since 2007, we have relocated our headquarters to sunny Southern California, San Diego (USA).
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Description
  • Weight
  • Dimensions
  • Additional information
  • Add to cart
Click outside to hide the comparison bar
Compare