Bench top pH/mV/conductivity/DO meter pHenomenal® MU 6100 L S1 kit
  • Large graphic LCD with continuous LED backlight shows the measured parameter and the temperature value simultaneously
  • Data logging function selectable between 1 min and 1 h; memory capacity of 5000 data sets
  • Automatic power shut-off: Adjustable from 10 min to 24 h
  • Automatic buffer recognition of DIN and NIST buffers (1,68 / 4,00 / 6,86 / 9,18 / 12,54)
  • Three additional technical buffers at 25 °C (4,00 / 7,00 / 10,00) in memory
  • Advanced self-test and diagnostics (electrode efficiency diagnostic, drift control); calibration symbol shows when recalibration is required
  • Low energy consumption. Choice of mains supply or 4× AA batteries for over 1000 operating hours

SPECIFICATIONS

Model MU 6100 L, S1 kit MU 6100 L, S2 kit
pH range −2,000… 19,999 −2,000… 19,999
pH resolution 0,1/0,01/0,001 (selectable) 0,1/0,01/0,001 (selectable)
pH accuracy ±0,1/±0,01/±0,005 ±0,1/±0,01/±0,005
pH calibration Up to 5 points Up to 5 points
Automatic buffer recognition VWR® Chemicals TITRINORM® buffers at 25 °C: 4,00/6,98/9,94
NIST/DIN 19266 (1,68/4,00/6,86/9,18/12,54)
Technical buffers at 25 °C: 4,00/7,00/10,00
VWR® Chemicals TITRINORM® buffers at 25 °C: 4,00/6,98/9,94
NIST/DIN 19266 (1,68/4,00/6,86/9,18/12,54)
Technical buffers at 25 °C: 4,00/7,00/10,00
mV range ±1200,0/±2500 ±1200,0/±2500
mV resolution 0,1/1 0,1/1
mV accuracy ±0,3/±1 ±0,3/±1
Conductivity range 0,001 µS/cm – 1000 mS/cm 0,001 µS/cm – 1000 mS/cm
Conductivity resolution 0,1 µS/cm 0,1 µS/cm
Conductivity accuracy ±0,5% of measured value ±0,5% of measured value
Conductivity cell constant 0,001 – 25 cm⁻¹ (depending on probe) 0,001 – 25 cm⁻¹ (depending on probe)
Conductivity calibration 1 point 1 point
Resistivity range 1 Ω/cm – 999 MΩ/cm 1 Ω/cm – 999 MΩ/cm
Resistivity accuracy ±0,5% of measured value ±0,5% of measured value
Salinity range 0,00 – 70 ppt 0,00 – 70 ppt
TDS range 0 – 1999 mg/L / 2,00 – 19,99 g/L / 20,0 – 199,9 g/L 0 – 1999 mg/L / 2,00 – 19,99 g/L / 20,0 – 199,9 g/L
TDS resolution 1 mg/L / 0,01 g/L / 0,1 g/L 1 mg/L / 0,01 g/L / 0,1 g/L
DO concentration (mg/L) 0,00 – 20,00; 0,0 – 90,0 0,00 – 20,00; 0,0 – 90,0
DO concentration resolution (mg/L) 0,1%; 0,01 (depending on sensor) 0,1%; 0,01 (depending on sensor)
DO saturation 0,0 – 200,0; 0 – 600 % (depending on sensor) 0,0 – 200,0; 0 – 600 % (depending on sensor)
DO accuracy ±0,5% of value (between 5…30 °C) ±0,5% of value (between 5…30 °C)
DO calibration Saturated air Saturated air
Temperature range Auto: −5,0… 105,0 °C; manual: −25… 130 °C Auto: −5,0… 105,0 °C; manual: −25… 130 °C
Temperature resolution 0,1/1 °C 0,1/1 °C
Temperature accuracy ±0,2 °C ±0,2 °C
Temperature compensation Automatic/manual Automatic/manual
Outputs Waterproof USB connection (slave, bidirectional) Waterproof USB connection (slave, bidirectional)
Display Graphic LCD with LED backlight Graphic LCD with LED backlight
Power supply Mains supply or 4× AA batteries Mains supply or 4× AA batteries
Compliance IP 43/GLP IP 43/GLP
Data logging – log function Selectable between 1 s and 1 h (selectable intervals: 1 s, 5 s, 10 s, 30 s, 1 min, 5 min, 10 min, 15 min, 30 min, 60 min) Selectable between 1 s and 1 h (selectable intervals: 1 s, 5 s, 10 s, 30 s, 1 min, 5 min, 10 min, 15 min, 30 min, 60 min)
Data logging capacity 5000 data sets 5000 data sets
Connections BNC for pH/banana for temperature/8-pin for conductivity and DO BNC for pH/banana for temperature/8-pin for conductivity and DO
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Description
  • Weight
  • Dimensions
  • Additional information
  • Attributes
  • Add to cart
Click outside to hide the comparison bar
Compare
0
0
×

Hello!

Click one of our contacts below to chat on WhatsApp

×